
Analog gauge reading
Turn the analog gauges your operators walk past into readings, trends and alarms — without touching the process.
The problem
Reads dial gauges, sight glasses, digital meters and valve positions from cameras, and sends readings with trends and limit alarms to your historian.
Brownfield plants have hundreds of analog gauges, sight glasses and local displays that were never connected to the control system. The only way to read them is to walk to them, and the readings end up on a clipboard or a tablet once or twice a shift.
That leaves long gaps in the data. A pressure that creeps up between rounds, a level that drops overnight or a misread value may not be noticed until it causes a trip or an alarm elsewhere. Rounds also take skilled time and send people into hot, noisy or remote areas.
Replacing every gauge with a smart transmitter means process isolation, wiring and shutdown windows — a cost that is hard to justify for instruments that only need to be read.

Where it falls short now.
- 01
Manual rounds give a few readings per shift, with gaps in between.
- 02
Hand-written or typed readings introduce transcription errors.
- 03
Retrofitting transmitters means process intrusion, wiring and shutdown windows.
- 04
Readings on paper never reach the historian, so trends and limits are not tracked.
From camera to action.
- 01
Capture
Existing cameras with a view of the gauge, or small fixed cameras added near gauge clusters, stream to Glance Edge.
- 02
Locate and read
Each gauge is located in the frame and its needle angle, level or digits read, using a per-gauge scale calibration.
- 03
Validate
Readings are checked for plausibility and image quality; glare, steam or an obstruction is flagged rather than reported as a value.
- 04
Act
Readings go to SCADA or the historian, and limit or rate-of-change alarms notify operators or raise work orders.
- 05
Trend
Trends sit alongside your other process data, so drift between rounds becomes visible.
Pipe rack with vapour leak, gauge reading and thermal hot spot.
What it sees, what it needs, what to measure.
- Dial gauge readings — pressure, temperature, flow
- Sight-glass and level indicator levels
- Digital meter and local display values
- Valve positions, open or closed
- Gauges that cannot be read because of glare, fogging or obstruction
- Existing IP cameras (RTSP / ONVIF) with a clear view of the gauge face
- Optional fixed cameras near gauge clusters
- Glance Edge box on site
- Per-gauge scale calibration during commissioning
- Historian or SCADA link for readings and alarms
- K1Reading error against manual reference readings, per gauge
- K2Share of readings flagged unreadable, and why
- K3Readings captured per gauge per day vs. manual rounds
- K4Limit excursions detected between rounds
- K5Operator time on rounds released for other work
Targets are agreed with you before the pilot starts and measured on your own sites.

One fixed camera can often read a whole cluster of gauges.
Built from these products.
How accurate are the readings?
Accuracy depends on camera resolution, distance, angle and the gauge scale. We measure it per gauge against manual readings during the pilot, rather than quoting a single number up front.
Do we need to modify the gauges or the process?
No — nothing touches the process. Where glare or viewing angle is a problem, a small fixed camera closer to the gauge cluster is the usual fix.
What data leaves the site?
Images are processed on the Glance Edge box on site, and readings go to your historian or SCADA. Video does not need to leave the site.
Related problems we solve.

Leak & spill detection
Per-camera baselines flag liquid on floors, steam and vapour, drips and spreading pools, and route each event to maintenance with an evidence clip.
Read the use case
PPE compliance
Worn-state PPE checks on your existing CCTV, with rules set per zone, shift and task, and one event per violation instead of an alert flood.
Read the use case
Forklift–pedestrian safety
Proximity, speeding and blind-corner risk measured in real distances on existing CCTV, with near-misses counted as a leading indicator by aisle and shift.
Read the use case
Let’s look at analog gauge reading on your site.
Start with a paid feasibility study on your own footage or samples. In one to two weeks you’ll know what can be detected, how accurately, and what it’s worth.