
Leak & spill detection
Learn what normal looks like on every camera — and flag the steam, vapour and liquid that should not be there.
The problem
Per-camera baselines flag liquid on floors, steam and vapour, drips and spreading pools, and route each event to maintenance with an evidence clip.
Leaks rarely start large. A weeping flange, a dripping valve stem or a slow seep under a pump grows over days, often in areas operators pass without stopping to look. By the time it is obvious there is product loss, a slip hazard, possible environmental reporting and sometimes an unplanned shutdown.
Most plants rely on operator rounds and fixed sensors at known risk points. Rounds are periodic and depend on attention; point sensors cover a spot, not an area, and cannot see a leak a few metres away.
Many plants already have CCTV over these areas, but nobody watches every screen, and generic motion analytics fire on people, vehicles, shadows and weather far more often than on leaks.

Where it falls short now.
- 01
Operator rounds are periodic, so leaks between rounds go unseen.
- 02
Point sensors detect at a spot, not across an area.
- 03
Motion-based video analytics flood the control room with alarms from people, rain and changing light.
- 04
Routine steam vents and wash-down water look like leaks to a model that does not know the site.
- 05
Findings are reported verbally and rarely tracked to a closed work order.
From camera to action.
- 01
Capture
Existing CCTV over pumps, pipe racks, tank areas and walkways streams to a Glance Edge box on site.
- 02
Learn the baseline
A normal baseline is built for each camera, by shift and time of day, so routine vents, wash-downs and lighting changes are expected rather than flagged.
- 03
Detect deviations
Targeted detectors for liquid on the floor, steam and vapour run alongside scene-level anomaly scoring. With PLC data, vapour near a closed valve is treated as a likely leak.
- 04
Act
Events reach the control room or maintenance with location, duration and an evidence clip, and can raise a work order.
- 05
Maintain
Drift monitoring refreshes the baseline as the plant changes, and housekeeping trends show where problems recur.
Pipe rack with vapour leak, gauge reading and thermal hot spot.
What it sees, what it needs, what to measure.
- Liquid on floors and spreading pools
- Drips and wet patches below pumps, flanges and valves
- Steam and vapour where none is expected
- Material and clutter in walkways
- Blocked exits and escape routes
- Daily housekeeping / 5S score per area
- Existing IP cameras (RTSP / ONVIF) over the areas of concern
- Glance Edge box on site
- Optional PLC / SCADA link for valve and pump states
- Optional thermal cameras where hot liquids or steam lines are involved
- Maintenance integration (SAP PM, IBM Maximo) for work orders
- K1Leaks and spills found by the system vs. found on rounds
- K2Time from first visible sign to alert
- K3False alarms per camera per day
- K4Time from alert to work-order closure
- K5Housekeeping score trend by area
Targets are agreed with you before the pilot starts and measured on your own sites.

Baselines are learned by shift and time of day, so night lighting is not mistaken for a leak.
Built from these products.
Sense Scene
Leaks, spills and clutter — flagged against your own baseline.
View product Early accessSense Machine
Video that knows what the machine is supposed to be doing.
View product Early accessSense Thermal
Hot spots found before they become failures.
View product RoadmapSense Gas
Gas imaging and detectors in the same pane of glass.
View productCan it detect gas leaks?
Not from ordinary cameras — most gases are invisible. Visible vapour and steam can be detected, and integration of partner optical gas imaging cameras and fixed detectors is on our roadmap as Sense Gas.
What about night shifts and changing light?
Baselines are learned per camera by shift and time of day, and drift monitoring refreshes them as conditions change. Areas with very poor night lighting are flagged in the feasibility study, where added lighting or thermal may be recommended.
What data leaves the site?
Video is processed on the Glance Edge box on site and faces are blurred on the device. Only the events, evidence clips and metrics you configure are sent onward.
Related problems we solve.

Analog gauge reading
Reads dial gauges, sight glasses, digital meters and valve positions from cameras, and sends readings with trends and limit alarms to your historian.
Read the use case
PPE compliance
Worn-state PPE checks on your existing CCTV, with rules set per zone, shift and task, and one event per violation instead of an alert flood.
Read the use case
Forklift–pedestrian safety
Proximity, speeding and blind-corner risk measured in real distances on existing CCTV, with near-misses counted as a leading indicator by aisle and shift.
Read the use case
Let’s look at leak & spill detection on your site.
Start with a paid feasibility study on your own footage or samples. In one to two weeks you’ll know what can be detected, how accurately, and what it’s worth.